Товаров
  
корзина пуста
  • Каталог оборудования Siemens

Metering pipes with orifice plate and annular chambers

  • Заказные данные
    (1)
  • Информационные материалы

    Область применения

    Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +400 °C.

    Дизайн

    Orifice plate with annular chambers consisting of two support rings with replaceable orifice disk form A or B (see types of primary differential pressure devices in "Technical description", "Function"); flanged between inlet and outlet pipe sections with lengths according to DIN 19205.

    Nominal diameters
    • EN: DN 10 to DN 50
    • ASME: ½ inch to 2 inch
    Nominal pressure
    • EN: PN 10 to PN 100
    • ASME: class 150 to 600
    Sealing face of the end flanges
    • Plane, sealing face turned, N10/N12 to DIN ISO 1302
    • Plane, sealing face turned, N8 to DIN ISO 1302
    • Plane, RF (raised faced) for versions to ASME
    Tapping sockets

    (For the dimensions of the following tapping sockets, see page 3/..)

    • With connection thread G½ DIN ISO 228/1, connection dimensions to DIN 19207 form V
    • With threaded connection ½-14 NPT male, for version to ASME
    • With Ø 12 mm pipe connection for pipe union with ferrule
    • With welding connection, Ø 21.3 mm

    For length of tapping sockets for all metering pipe L = 120 mm and position of tapping socket, see "Technical Description" and "Function".

    Чертеж

    Nominal diameter acc. to EN

    DN

    PN

    a

    L

    k

    Pipe1)

    Da x s

    Weight

    kg

    10

    10 and 16

    400

    218

    320

    16 x 3

    4.5

    25 and 40

    320

    5

    63 and 100

    295

    6,5

    15

    10 and 16

    550

    368

    325

    20 x 2.5

    5

    25 and 40

    325

    5.5

    63 and 100

    300

    7.5

    20

    10 and 16

    700

    488

    335

    25 x 2.5

    6.5

    25 and 40

    7

    25

    10 and 16

    900

    638

    310

    30 x 2.5

    8

    25 and 40

    9

    63 and 100

    14

    32

    10 and 16

    1100

    788

    320

    38 x 3

    11.5

    25 and 40

    12.5

    40

    10 and 16

    1300

    988

    330

    48. 3 x 3.6 or 50 x 5

    13

    25 and 40

    330

    15

    63 and 100

    335

    25

    50

    10 and 16

    1500

    1188

    340

    60 x 5

    20

    25 and 40

    340

    22

    63

    345

    34

    100

    345

    34



    Metering pipes with orifice plates and annular chambers for installation between EN flanges to EN 1092.1, dimensions in mm and weights

    1) The stated pipe dimensions may vary, depending on availability. The pipe dimensions used can be found in the calculation for primary differential pressure devices and/or in the order confirmation.

    Nominal diameter acc. to ASME

    ASME

    PN

    a

    L

    k

    Pipe1)

    Da x s

    Weight

    kg

    ½ inch

    Class 150

    550

    368

    297

    20 x 2.5

    5

    Class 300

    307

    5.5

    Class 600

    307

    7.5

    ¾ inch

    Class 150

    700

    488

    297

    25 x 2.5

    6.5

    Class 300

    307

    7

    Class 600

    307

    8

    1 inch

    Class 150

    900

    638

    307

    30 x 2.5

    8

    Class 300

    313

    9

    Class 600

    313

    14

    1¼ inch

    Class 150

    1100

    788

    316

    38 x 3

    11.5

    Class 300

    322

    12.5

    Class 600

    322

    14

    1½ inch

    Class 150

    1300

    988

    326

    48. 3 x 3.6 or 50 x 5

    13

    Class 300

    335

    15

    Class 600

    335

    25

    2 inch

    Class 150

    1500

    1188

    345

    60 x 5

    20

    Class 300

    371

    22

    Class 600

    351

    34



    Metering pipes with orifice plates and annular chambers for installation between ASME flanges to ASME B 16.5, dimensions in mm and weights

    1) The stated pipe dimensions may vary, depending on availability. The pipe dimensions used can be found in the calculation for primary differential pressure devices and/or in the order confirmation.