Товаров
  
корзина пуста
  • Каталог оборудования Siemens

SITRANS F R rotary-piston meters

  • Информационные материалы

    Информационные материалы

    Mechanical registers, automatic batchmeters and digital registers with current and pulse output

    Rotary piston meter DN 25 (1") with single-pointer dial type 01

    Rotary piston meter with electric flow register in compact form

    Rotary piston meter DN 50 (2") with mech. single-pointer dial .type 01, with accessories (here: cooling attachment and pulser)

    Automatic batchmeter DN 50 (2"), with rotary piston meter, quantity preset register and shut-off valve

    Selection overview, rotary piston meters
         
       

    Version

    Rotary piston meters

    Nominal diameter

    DN 15

    DN 25

    DN 50

    DN  80

    Article No.

    7MR10..-...

    7MR11..-...

    7MR14..-...

    7MR16..-...

    Nominal pressure

    PN 6

      

     

    PN 10

     

      

    PN 16

     

     

    PN 25

    PN 40

     

    PN 63

     

     

    Flow variables

    Max. 20 l/min

       

    Max. 100 l/min

     

      

    Max. 500 l/min

      

     

    Max. 1 000 l/min

       

    Flange standards

    Drilled acc. to EN

    Drilled acc. to ASME

    With raised faces

    Approvals

    Custody transfer

     

    Material acceptance test to EN 10204-3.1

    ATEX

    in preparation

    Piston materials

    Carbon

    Cast iron

    Ni-resist

     

    Hard rubber

    PTFE 40 °C

     

    PTFE 90 °C

     

    CrNiMo steel with carbon contact surface

     

      

    CrNiMo steel with PTFE contact surface

     

      

    PCTFE

     

    Designs

    Mechanical single-pointer dial

    Mechanical double-pointer dial

    As automatic batchmeter (incl. shut-off valve)

     

     

    With electronic flow register

    Remote or compact installation



    Дизайн

    Metering mechanism of a rotary-piston meter DN 25/PN 10 (1“/MWP 145 psi) (industrial model)

    The measuring chamber is inserted into the case for the rated pressure classes PN 25, PN 40 and PN 63 (MWP 363, 580 and 914 psi). The meters for rated pressures PN 4, PN 6 and PN 10 (MWP 58, 87 and 145 psi) have a measuring chamber machined to the lower part of the case.

    All components of the meters are made of wear-resistant materials. Several materials are available for the parts which come into contact with the metered liquid (see Selection and Ordering data). The most suitable combination can be selected taking into account the corrosion resistance with respect to the liquid to be measured as well as the running characteristics and the permissible temperatures.

    Конфигурация

    Error curves of rotary-piston meters

    The shape of the error curve is also affected by the viscosity of the metered liquid. The error in measurement increases with decreasing viscosity, especially at the beginning and towards the end of the flow rate range.

    By appropriate regulation, i.e. changing a pair of gear-wheels between the meter mechanism and the register, the position of the error curve can be displaced parallel to the zero line and thus the meter can be optimally calibrated. The appropriate pair of replacement gears can be read off from a table or determined with the aid of a calculating disk.

    The illustration “Error curves of volumetric meters” shows error curves without any regulation having been carried out.

    Error curves of volumetric meters dependent in shape and location on the flow rate and the viscosity of the liquid

    Note: 1 mPa·s = 1 cp

    Measuring accuracy

    The rotary-piston meters are approved in the European Community and in many other countries for the custody transfer.

    The following error limits apply between 0.2 % and 0.5 % of the correct value (depending on the liquid, the measuring range and the relevant calibration specifications).

    The stated error limits in % of the correct value apply to the whole flow rate and for any delivery quantity greater than the smallest permissible quantity.

    This is an important difference compared to other measuring instruments whose errors are related to the full-scale value and thus only reach the stated accuracy at one point - full-scale deflection. The minimum flow rate should not fall below 10 % of the maximum flow rate in order to remain within the stated accuracy limit. This explains why the usual flow rate range for volumetric meters is 1:10.

    Note: The measuring system of the rotary-piston meter must always be filled with the liquid to be measured in order to achieve a high measuring accuracy.

    Note

    The material combinations which can be supplied are listed in the Selection and Ordering data.
    The maximum permissible liquid temperature is determined by the “weakest link” in the particular combination (the PCTFE rotary-piston, for example, in a meter made of Cranium steel).

    Service life (long-term accuracy)

    The service life of a volumetric meter, i.e. the operating time until an overhaul or recalibration becomes necessary, is determined by the mechanical abrasion of the moving parts of the mechanisms which occurs because of forces from the metered liquid.

    As well as the nature of the materials used (running characteristics), the service life is dependent on the lubricating properties of the metered liquid, the service is dependent on the lubricating properties of the metered liquid, the daily operating time and the cube of the flow rate (speed of rotation). The last factor is one of the reasons why only half of the maximum flow rate specified for the batch operation is permissible for continuous operation.

    Since the above factors can hardly be determined exactly with industrial use of the meter, unequivocal statements on the service life (long-term accuracy) are not possible.

    Recalibration is required every two years by law (in Germany) for meters used for custody transfer. On the basis of this regulation, it is recommended that meters which are not used for custody transfer be checked and recalibrated if necessary, at intervals of two to three years. Even this recommendation is based on average, “normal” operating conditions. A period of three years is too short, for example, for a meter used for the batch dispensing of lubricating oil, it will still work within the stated error limits even after five years or more.

    Rotary piston meters - Configurations
     

    Mechanical displays

    Digital displays

     

    Compact design

    As separate model

    Compact design

     

    Without pulse and current output

    With pulse and current output

    With pulse and current output

    Incl. protective cover

    With pulse and current output

    Incl. mounting bracket

    Registers

    Single-pointer dial, type 01

     

      

    Double-pointer dial, types 11 and 12

      

    Quantity preset register

      

    SITRANS F RA110 electric flow registers (7MV1070-...)

          
    • Without mounting bracket
        

     
    • With mounting bracket
         

    Pulser

    10 pulses/revolution,
    100 pulses/revolution

        

    10 pulses/value per revolution,
    100 pulses/value per revolution

     

       

    Intermediate gear

    (Part of Article No. of the rotary piston meter)

     

      

    Pulser

    10 Impulse/measuring chamber volumes

    100 Impulse/measuring chamber volumes

    (Selection with data position 14 of Article No. of the rotary piston meter)

       

      

    Cooling attachment

    Up to 80 °C: none
    (Article No. 7MR1...-.....-....)

     

    Up to 180 °C: one
    (Article No. 7MR1...-.....-.... + 7MV3001-1xx00)

    Upt to 260 °C: two
    (Article No. 7MR1...-.....-.... + 7MV3001-2xx00)

    Rotary piston meters and automatic batchmeters

    Rotary piston meters

    DN 15: 7MR10..-...

    DN 25: 7MR11..-...

    DN 50: 7MR14..-...

    DN 80: 7MR16..-...

    Automatic batchmeters

    DN 25: 7MR111.-...

    DN 50: 7MR141.-...

    ≤ PN 16

    PN 25 … PN 63

    Measuring chamber volumes:

    DN 15 (1/2“): 0.033 l (0.0087 USgpm)

    DN 25 (1“): 0.179 l (0.0473 USgpm)

    DN 50 (2“): 1.5 l (0.317 USgpm)

    DN 80 (3“): 4.32 l (1.14 USgpm)



    Чертеж

    Rotary-piston meter with single pointer dial and intermediate gear
     
       
     

    DN 25

    DN 50

    DN 80

    DN 15

    DN 25

    DN 50

    DN 80

    PN 25

    PN 40

    PN 25 und PN 40

    PN 63

    PN 25 und PN 40

    PN 63

    PN 25 und PN 40

    PN 63

    L

    210 (8.27)

    325 (12.80)

    410 (16.14)

    200 (7.87)

    200 (7.87)

    270 (10.63)

    300 (11.81)

    400 (15.75)

    470 (18.50)

    540 (21.26)

    600 (23.62)

    C

    90 (3.54)

    147 (5.79)

    185 (7.28)

    -

    -

    -

    -

    -

    -

    -

    -

    C1

    -

    -

    -

    50 (1.97)

    68 (2.68)

    80 (3.15)

    82 (3.23)

    120 (4.72)

    120 (4.72)

    155 (6.10)

    177 (6.97)

    C2

    -

    -

    -

    83,5 (5.67)

    108 (4.25)

    144 (5.67)

    157 (6.18)

    205 (8.07)

    230 (9.06)

    271 (10.67)

    312 (12.28)

    a3

    153 (6.02)

    205 (8.07)

    244 (9.61)

    140 (8.19)

    165 (6.50)

    208 (8.19)

    224 (8.82)

    263 (10.35)

    285 (11.22)

    331 (13.03)

    387 (15.24)



    Automatic batchmeter with quantity preset register intermediate gear
      
     
     

    PN 25

    PN 50

    L1

    210 (8.27)

    325 (12.80)

    L2

    135 (5.31)

    175 (6.89)

    C

    90 (3.54)

    147 (5.79)

    a3

    153 (6.02)

    205 (8.07)



    In addition to dimension a3 the following dimensions need to be added for extra add-on components (dimensions in mm (inch))

    Addition of

    a3 +

    Intermediate gear

    37 (1.46)

    Single-pointer dial type 01

    47 (1.85)

    Double-pointer dial type 11

    58 (2.28)

    Double-pointer dial type Typ 12

    250 (9.84)

    Pulser

    82 (3.23)

    Mounting bracket and electronic flow register

    200 (7.87)

    1 additional insulation attachment (up to 180°C (176°F))

    159 (6.26)

    2 additional insulation attachments

    318 (12.52)

    Quantity preset register

    287 (11.30)



    Особенности

    • High measuring accuracy (approved for custody transfer)
    • Suitable for flow rates up to 1000 l/min (264 USgpm)
    • Wide flow rate range
    • Low dependence on viscosity
    • Low pressure drop
    • Simple compact design
    • High reliability
    • Advantages with extremely high viscosity since pressure drops up to 3 bar (43.5 psi) permissible
    • Advantages with very low viscosity (e. g. liquefied gas) since only low pressure drops occur because of the light-weight mechanism with good running characteristics
    • Wide range of available materials, e. g. plastic lining for particularly corrosive liquids
    • Easy service as a result of simple design
    • Liquid temperatures up to 300 °C
    • Also available with external heater
    • Metering and dispensing without a power supply
    • No inlet or outlet pipe sections required
    • Independent of flow profile, conductivity and damping

    Rotary-piston meters are characterized by:

    • Accuracy
    • Reliability
    • Robust design

    Технические данные

    Further technical specifications

    Materials and max. permissible liquid temperatures

     

    Housing (also lining with acid resistant meters) and measuring chamber

    Temperature range

    • Cast iron, spheroidal graphite, cast steel, Cranium steel

    -30 … +300 °C (-22 … +572 °F)

    General data

     

    Error limits

    Between 0.2 % and 0.5 % of the correct value (depending on the metered fluid, the measuring range and the relevant calibration regulations) except for rotary-piston meters DN 15 (½“) and acid-resistant meters with PCTFE pistons; where 1 % of the actual value applies.

    Reproducibility

    Within 0.05 %

    Adjustment

    In steps from 0.01 %

    Pressure drop

    Max. permissible 3 bar (43.5 psi), max. 0.5 bar (7.25 psi) for acid resistant meters

    Transmission from wet to dry space

    Gland-free, via permanent magnet coupling

    Installation position (axis of meter mechanism)

     
    • Rotary-piston meter for industrial use
     
    • Automatic batchmeter

    Vertical

    • Special designs
     
    • Rotary-piston meter for oil fuels

    Any

    • Rotary-piston meter for liquid gas

    Meter axis vertical

    Special inlet and outlet pipe sections

    Not necessary

    Pipe connection

    Flanges drilled to DIN 2501, DIN 2547 (PN 63 only)

    Filter size (mesh width)

    0.8 mm (0.031 inch) for rotary-piston meter



    Meter sizes (DN), pressure stages (PN) and permissible flow rates (q) for rotary-piston meters and automatic batchmeters

    Design

    DN

    PN

    Rated flow rate

    Permissible flow rate

    With viscosity8)

    Min.1) with continuous2) operation

    Max. with intermittent3)4) operation

    Max. with continuous operation

     

    mm

    (inch)

    bar

    (psi)

    l/min

    (USgpm)

    mPa·s (cp)

    l/min

    (USgpm)

    l/min

    (USgpm)

    l/min

    (USgpm)

    Rotary-piston meters for industrial use

    up to PN 16 (MWP 232 psi)

    up to PN 63 (MWP 914 psi)

    155)

    (½)5)

    25

    (363)

    20

    (5.3)

    ≤ 1
    < 5
    800
    2000

    1.5
    1.0
    0.2
    0.2

    (0.26)
    (0.2)
    (0.05)
    (0.03)

    106)
    20
    20
    10

    (5.3)
    (5.3)
    (5.3)
    (1.3)

    10
    10
    10
    5

    (2.6)
    (2.6)
    (2.6)
    (1.3)

    25

    (1)

    10
    16
    25
    40
    63

    (145)
    (232)
    (363)
    (580)
    (914)

    100

    (26.4)

    0,3
    0,6
    1
    5
    800

    12
    6
    5
    3
    1

    (3.2)
    (1.6)
    (1.3)
    (0.8)
    (0.26)

    100
    100
    100
    100
    100

    (26)
    (26)
    (26)
    (26)
    (26)

    80
    80
    80
    80
    80

    (13)
    (13)
    (13)
    (13)
    (13)

    50

    (2)

    6
    16
    25
    40
    63

    (87)
    (232)
    (363)
    (580)
    (914)

    500

    (132)

    0.3
    0.6
    1
    5
    800

    40
    20
    18
    10
    2

    (11)
    (5.3)
    (4.8)
    (2.6)
    (0.53)

    500
    500
    500
    500
    500

    (106)
    (132)
    (132)
    (132)
    (106)

    350
    350
    350
    350
    350

    (44)
    (44)
    (44)
    (44)
    (44)

    80

    (3)

    25
    40

    (363)
    (580)

    1000

    (264)

    0.3
    0.6
    1
    5
    800

    60
    35
    25
    10
    5

    (16)
    (9.3)
    (6.6)
    (2.6)
    (1.3)

    1000
    1000
    1000
    1000
    1000

    (211)
    (264)
    (264)
    (264)
    (211)

    700
    700
    700
    700
    500

    (93)
    (93)
    (93)
    (93)
    (93)

    Automatic batchmeter (Rotary-piston meter with quantity preset register and mechanical shut-off valve)

     

    25

    (1)

    10

    (145)

    100

    (26.4)

    0.3
    0.6
    1
    5
    8007)

    12
    6
    5
    3
    1

    (3.2)
    (1.6)
    (1.3)
    (0.8)
    (0.26)

    100
    100
    100
    100
    100

    (26)
    (26)
    (26)
    (26)
    (26)

    -

    -

    50

    (2)

    6
    10

    (87)
    (145)

    500

    132

    0.3
    0.6
    1
    5
    8007)

    40
    20
    18
    10
    2

    (11)
    (5.3)
    (4.8)
    (2.6)
    (0.53)

    500
    500
    500
    500
    400

    (106)
    (132)
    (132)
    (132)
    (106)

    -

    -



    1) For metal rotary-pistons: increase by a factor of 2, for PCTFE and PTFE/graphite filling rotary-pistons: increase by a factor of 3.

    2) Continuous operation: over 8 hours a day.

    3) For metal pistons: reduce by a factor ≈ 0.8 to extend service life

    4) Intermittent operation: up to 8 hours a day

    5) Note: When using pistons made of carbon, there is danger of break in the case of liquid hammers

    6) When using pistons made of carbon.

    7) Max. permissible viscosity for exact closing of the shut-off valve and for exact dispensing; viscosities up to around 4000 mPa·s (cp) possible.

    8) Higher viscosity on request.

    Note:
    In order to extend the service life of the pulse sensor, rotary-piston meters with current and/or pulse output (without intermediate gear) should only be operated at max. 60 % of the permissible flow.

    Piston materials

    Piston material

    Design

    Permissible liquid temperature (°C/°F)

    Max. perm. dyn. Viscosity (mPa·s (cp))

    Article No. code

    Carbon

     

    -10 … 300/14 … 572

    25

    K

    Cast iron (mat. No. GG 25)
    Cast iron (mat. No. GG 25)


    with slotting

    -10 … 300/14 ... 572
    -10 … 300/14 ... 572

     

    E
    B

    Ni-Resist (mat. No. 0.6660)
    Ni-Resist (mat. No. 0.6660)


    with slotting

    -10 … 300/14 ... 572
    -10 … 300/14 ... 572

     

    N
    C

    Hard rubber
    Hard rubber


    with slotting

    -10 … +401)/14 ... 1041)
    -10 … +401)/14 ... 1041)

    50
    50

    G
    D

    PTFE/graphite filling
    PTFE/graphite filling
    PTFE/graphite filling
    PTFE/graphite filling


    with slotting

    with slotting

    0 … 402)/32 … 1042)
    0 … 402)/32 … 1042)
    0 … 902)/32 … 1942)
    0 … 902)/32 … 1942)

    120
    120
    120
    120

    F
    L
    R
    M

    PCTFE
    PCTFE


    with slotting

    -10 … +402/14 … 1042)/
    -10 … +402/14 … 1042)

    120
    120

    H
    J

    CrNi steel with carbon contact surface (only DN 25 (1“))
    CrNi steel with PTFE contact surface (only DN 25 (1“))

    Collar piston

    -10 … +200/14 ... 392
    -10 … +40/14 ... 104

    > 10
    > 10

    S
    T



    1) For 120 min max. 65 °C (149 °F); for 20 min max. 90 °C (194 °F), e.g. for cleaning procedures

    2) Error limit max. 1 %, at 90 °C (194 °F) max. 2 %.