Товаров
  
корзина пуста
  • Каталог оборудования Siemens

SIPLUS Control Units CU310-2 for single-axis drives

  • Заказные данные
    (2)
  • Аксессуары
    (1)
  • Информационные материалы

    Информационные материалы

    SINAMICS S120, CU310-2 PN and CU310-2 DP

    The CU310-2 control unit is designed for the communication and open-loop/closed-loop control functions of a SINAMICS S120 (AC/AC) and is combined with the PM340 power module to create a powerful single-axis drive. A PROFINET (PN) variant and a PROFIBUS (DP) variant are available for fieldbus communication.

    The SIPLUS S120 Basic Operator Panel (BOP) is available as an accessory. The operating device has a miniature 2-line display, 6 keys for parameterization and diagnostics and is suitable for use with CU305, CU310 and CU320 Control Units.

    Note:

    SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the corresponding standard products. SIPLUS extreme-specific information was added.

    Технические данные

    Order number

     

    6AG1040-1LA00-2AA0

    6AG1040-1LA01-2AA0

    product brandname

     

    SIPLUS

    Product designation

     

    Controller

    General technical data:

     

     

     

    Design of the product

     

    CU310-2 DP

    CU310-2 PN

    Product function

     

     

     

    • ● vector control with encoder

     

    No

    • ● vector control without encoder

     

    Yes

    Product function for U/f control

     

     

     

    • ● ECO mode linear or quadratic

     

    No

    • ● flux current control

     

    No

    • ● linear or quadratic parameterization

     

    No

    Operating voltage

     

     

     

    • ● from external supply voltage

    V

    28.8 ... 20.4

    • ● from power module

    V

    24

    Input voltage at analog inputs as voltage inputs

     

     

     

    • ● for signal <0> to <1>

    V

    0

    Consumed current maximum

    A

    0.3

    AWG number as coded connectable conductor cross section for signal line

     

    30 ... 16

    Power loss [W] maximum

    W

    20

    Protection class IP

     

    IP20

    Width

    mm

    73

    Height

    mm

    191

    Depth

    mm

    75

    Net weight

    kg

    0.95

    Inputs/ Outputs:

     

     

     

    Type of analog input

     

    Differential input

    Number of analog inputs

     

    1

    • ● Note

     

    The differential analog inputs can be configured as supplementary digital inputs

    Number of digital inputs

     

    11

    • ● Note

     

    According to IEC 61131-2 type 1, 5 floating digital inputs, 8 bidirectional non-floating digital inputs/outputs, 3 parameterizable failsafe digital inputs (electrically isolated) or, alternatively, 6 parameterizable digital inputs (electrically isolated)

    Number of digital inputs with fail-safe

     

    3

    • ● Number of digital inputs with fail-safe Note

     

    optionally parameterizable as safe inputs

    Number of digital outputs as relay change-over contact

     

    0

    Number of digital outputs as transistor

     

    0

    Communication:

     

     

     

    Number of interfaces

     

     

     

    • ● acc. to RS 485

     

    1

    0

    • ● acc. to PROFINET

     

    0

    2

    Protocol is supported PROFIBUS protocol

     

    Yes

    No

    Ambient conditions:

     

     

     

    Relative humidity maximum

    %

    100

    • ● Note

     

    RH, incl. condensation/frost permitted (no commissioning in bedewed state)

    Ambient temperature

     

     

     

    • ● during operation

     

    -20 ... +55

    • ● during storage

     

    -40 ... +70

    Ambient temperature [°F]

     

     

     

    • ● during operation

     

    -4 ... +131

    • — Note

     

    A derating of 3 K/1000 m has to be applied to the Control Units from an installation altitude of 1000 m above sea level

    • ● during storage

     

    -40 ... +158

    Resistance to biologically active substances conformity acc. to EN 60721-3-3

     

    Yes

    Resistance to biologically active substances

     

    Class 3B2 acc. to EN 60721-3-3, mold and fungal spores (except fauna)

    • ● conformity acc. to EN 60721-3-3 Note

     

    The supplied plug covers must remain in place over the unused interfaces during operation!

    conformity acc. to EN 60721-3-3

     

    Yes

    Resistance to chemically active substances

     

    Class 3C4 acc. to EN 60721-3-3, including salt spray acc. to EN 60068-2-52 (severity level 3)

    • ● conformity acc. to EN 60721-3-3 Note

     

    Compliant with EN 60721-3-3, Class 3C4 incl. salt spray in accordance with EN 60068-2-52 (severity 3); the supplied plug covers must remain in place on the unused interfaces during operation.

    Resistance to mechanically active substances conformity acc. to EN 60721-3-3

     

    No

    Certificate of suitability

     

    CE / TÜV

    Certificate of suitability for CE marking

     

    Low-voltage directive 2006/95/EC


    Order number

     

    6AG1055-0AA00-2BA0

    product brandname

     

    SIPLUS

    Product designation

     

    Controller

    General technical data:

     

     

    Design of the product

     

    BOP 20

    Product function

     

     

    • ● vector control with encoder

     

    No

    • ● vector control without encoder

     

    No

    Product function for U/f control

     

     

    • ● ECO mode linear or quadratic

     

    No

    • ● flux current control

     

    No

    • ● linear or quadratic parameterization

     

    No

    AWG number as coded connectable conductor cross section for signal line

     

    0 ... 0

    Protection class IP

     

    IP20

    Width

    mm

    49

    Height

    mm

    48

    Depth

    mm

    8

    Net weight

    kg

    0.05

    Inputs/ Outputs:

     

     

    Number of analog inputs

     

    0

    Number of digital inputs

     

    0

    Number of digital inputs with fail-safe

     

    0

    Number of digital outputs as relay change-over contact

     

    0

    Number of digital outputs as transistor

     

    0

    Communication:

     

     

    Number of interfaces

     

     

    • ● acc. to RS 485

     

    0

    • ● acc. to PROFINET

     

    0

    Protocol is supported PROFIBUS protocol

     

    No

    Ambient conditions:

     

     

    Relative humidity maximum

    %

    100

    • ● Note

     

    RH, incl. condensation/frost permitted (no commissioning in bedewed state)

    Ambient temperature

     

     

    • ● during operation

     

    -20 ... +70

    • ● during storage

     

    -40 ... +70

    Ambient temperature [°F]

     

     

    • ● during operation

     

    -4 ... +158

    • — Note

     

    A derating of 3 K/1000 m has to be applied to the Control Units from an installation altitude of 1000 m above sea level

    • ● during storage

     

    -40 ... +158

    Resistance to biologically active substances conformity acc. to EN 60721-3-3

     

    Yes

    Resistance to biologically active substances

     

    Class 3B2 acc. to EN 60721-3-3, mold and fungal spores (except fauna)

    • ● conformity acc. to EN 60721-3-3 Note

     

    The supplied plug covers must remain in place over the unused interfaces during operation!

    conformity acc. to EN 60721-3-3

     

    Yes

    Resistance to chemically active substances

     

    Class 3C4 acc. to EN 60721-3-3, including salt spray acc. to EN 60068-2-52 (severity level 3)

    • ● conformity acc. to EN 60721-3-3 Note

     

    Compliant with EN 60721-3-3, Class 3C4 incl. salt spray in accordance with EN 60068-2-52 (severity 3); the supplied plug covers must remain in place on the unused interfaces during operation.

    Resistance to mechanically active substances conformity acc. to EN 60721-3-3

     

    No

    Certificate of suitability

     

    CE

    Certificate of suitability for CE marking

     

    EN 61800-3