HydroRanger 200 HMI

  • Заказные данные
    (1)
  • Аксессуары
    (33)
  • Информационные материалы

    Информационные материалы

    HydroRanger 200 HMI is an ultrasonic level controller for up to six pumps and provides control, differential control, and open channel flow monitoring.

    Область применения

    For water authorities, municipal water, and wastewater plants, HydroRanger 200 HMI is an economical, low-maintenance solution delivering control efficiency and productivity needed to meet today’s exacting standards. It offers single point monitoring with all models, and optional dual-point monitoring with 6 relay model. As well, it has digital communications with built-in Modbus RTU via RS 485.

    The standard 6 relay HydroRanger 200 HMI will monitor open channel flow and features advanced relay alarming and pump control functions as well as volume conversion. It is compatible with SIMATIC PDM, allowing for PC configuration and set-up. Sonic Intelligence advanced echo-processing software provides increased reading reliability.

    HydroRanger 200 HMI uses proven continuous ultrasonic echo ranging technology to monitor water and wastewater of any consistency up to 15 m (50 ft) in depth. Achievable resolution is 0.1 % with accuracy to 0.25 % of range. Unlike contacting devices, HydroRanger 200 HMI is immune to problems caused by suspended solids, harsh corrosives, grease or silt in the effluent, reducing downtime.

    • Key Applications: wet wells, flumes/weirs, bar screen control

    Чертеж

    HydroRanger 200 HMI, dimensions in mm (inch)

    Особенности

    • Easy to use HMI display with local four-button programming, menu-driven parameters, and Wizard support for key applications
    • English, German, French, Spanish, Chinese, Italian, Portuguese, and Russian texts on the HMI
    • Removable terminal blocks for ease of wiring
    • Monitors wet wells, weirs, and flumes
    • Communication using built-in Modbus RTU via RS 485 and SIMATIC PDM configuration software
    • Compatible with SmartLinx system: PROFIBUS DP (cyclic access of process values only) and DeviceNET
    • Single or dual point level monitoring
    • 6 relays
    • Auto False-Echo Suppression for fixed obstruction avoidance
    • Anti-grease ring/tide mark buildup
    • Differential amplifier transceiver for common mode noise rejection and improved signal-to-noise ratio
    • Wall and panel mounting options

    Схема подключения

    HydroRanger 200 HMI connections

    Технические данные

    Mode of Operation

     

    Measuring principle

    Ultrasonic level measurement

    Measuring range

    0.3 ... 15 m (1 ... 50 ft), transducer dependent

    Measuring points

    1 or 2

    Input

     

    Analog

    0 ... 20 mA or 4 ... 20 mA, from alternate device, scalable (6 relay model)

    Discrete

    10 ... 50 V DC switching level Logical 0 ≤ 0.5 V DC Logical 1 = 10 ... 50 V DC max. 3 mA

    Output

     

    EchoMax transducer

    44 kHz

    Ultrasonic transducer

    Compatible transducers: ST-H and EchoMax series XPS-10, XPS-15/15F, and XRS-5

    Relays1)

    Rating 5 A at 250 V AC, non-inductive

    • Model with 6 relays

    4 SPST Form A/2 SPDT Form

    mA output

    0 ... 20 mA or 4 ... 20 mA

    • Max. load

    750 Ω, isolated

    • Resolution

    0.1 % of range

    Accuracy

     

    Error in measurement

    0.25 % of range or 6 mm (0.24 inch), whichever is greater

    Resolution

    0.1 % of measuring range or 2 mm (0.08 inch), whichever is greater2)

    Temperature compensation

    • -50 ... +150 °C (-58 ... +302 °F)
    • Integral temperature sensor in transducer
    • External TS-3 temperature sensor (optional)
    • Programmable fixed temperature values

    Rated operating conditions

     

    Installation conditions

     
    • Location

    Indoor / outdoor

    • Installation category

    II

    • Pollution degree

    4

    Ambient conditions

     
    • Ambient temperature (enclosure)

    -20 ... +50 °C (-4 ... +122 °F)

    Design

     

    Weight

     
    • Wall mount

    1.22 kg (2.68 lb)

    • Panel mount

    1.35 kg (2.97 lb)

    Material (enclosure)

    Polycarbonate

    Degree of protection (enclosure)

     
    • Wall mount

    IP65/Type 4X/NEMA 4X

    • Panel mount

    IP54/Type 3/NEMA 3

    Cable

     
    • Transducer and mA output signal

    2-core copper conductor, twisted, shielded, 300 Vrms, 0.82 mm² (18 AWG), Belden 8 760 or equivalent is acceptable

    • Max. separation between transducer and transceiver

    365 m (1 200 ft)

    Displays and controls

    60 x 40 mm (2.36 x 1.57 inch) LCD 240 x 160 pixels resolution

    Power supply3)

     

    AC version

    100 ... 230 V AC ± 15 %, 50/60 Hz, 36 VA (17 W)

    DC version

    12 ... 30 V DC (20 W)

    Certificates and approvals

    • CE, RCM4)
    • FM, CSAUS/C, UL listed
    • CSAUS/C Class I, Div. 2, Groups A, B, C and D, Class II, Div. 2, Groups F and G, Class III (wall mount only)
    • MCERTS Class 2 approved for Open Channel Flow

    Communication

    • RS 232 with Modbus RTU or ASCII via RJ-11 connector
    • RS 485 with Modbus RTU or ASCII via terminal blocks
    • Optional: SmartLinx cards for
      • PROFIBUS DPV1 (cyclic access of process values only)
      • DeviceNet


    1) All relays certified for use with equipment that fails in a state at or under the rated maximums of the relays.2) Program range is defined as the empty distance to the face of the transducer plus any range extension.3) Maximum power consumption is listed 4) EMC performance available upon request