Товаров
  
корзина пуста
  • Каталог оборудования Siemens

Plug-in transceivers for SCALANCE X-300 managed

  • Заказные данные
    (9)
  • Информационные материалы

    Информационные материалы

    • Plug-in transceivers offer the capability of flexibly equipping the modular SCALANCE X-300 Industrial Ethernet switches for optical connections
    • With an operating temperature range from -40 °C to +70 °C, the plug-in transceivers are especially suited for use in demanding environments
    • All specified plug-in transceivers are tested for use with SCALANCE devices
    • There are different versions that differ depending on suitable fiber types, range, and bandwidth

    Modular SCALANCE XR324-12M

    Product versions

    SFP (small form-factor pluggable) transceivers can only be used together with the MM992-2SFP media module in the modular X-300 Industrial Ethernet switches.

    MM992-2SFP media module with SFP plug-in transceiver

    Optical SFP plug-in transceivers with 1 x 100 Mbps LC port

    • SFP991-1 multi-mode, glass, up to 5 km
    • SFP991-1LD single-mode, glass, up to 26 km
    • SFP991-1LH+ single-mode, glass, up to 70 km
    • SFP991-1ELH200 single-mode, glass, up to 200 km

    Optical SFP plug-in transceivers with 1 × 1000 Mbps LC port

    • SFP992-1 multi-mode, glass, up to 750 m
    • SFP992-1LD single-mode, glass, up to 10 km
    • SFP992-1LH single-mode, glass, up to 40 km
    • SFP992-1LH+ single-mode, glass, up to 70 km
    • SFP992-1ELH single-mode, glass, up to 120 km

    Дизайн

    • Operating temperature range of the SFP plug-in transceivers from -40 °C to +70 °C
    • SFP plug-in transceivers have an LC connection
    • IP20 degree of protection

    Особенности

    • Cost savings due to the modular system. The modular system allows the setup of electrical and optical Industrial Ethernet networks and the network topology and port type to easily be adapted to the plant structure and expanded at any time
    • Integrated industrial network for data, speech, and video; high performance due to Gigabit ports

    Технические данные

    Order number

    6GK5991-1AD00-8AA0

    6GK5991-1AF00-8AA0

    6GK5991-1AE00-8AA0

    6GK5991-1AE30-8AA0

    Product type designation

    SFP991-1

    SFP991-1LD

    SFP991-1LH+

    SFP991-1ELH200

    Interfaces

     

     

     

     

    Number of electrical/optical connections for network components or terminal equipment maximum

    1

    1

    1

    1

    Number of optical interfaces for network components or terminal equipment maximum

    1

    1

    1

    1

    Number of 100 Mbit/s LC ports

    1

    1

    1

    1

    Design of the optical interface for network components or terminal equipment

    LC

    LC

    LC

    LC

    Wavelength of the optical interface

    1 310 nm; Multi-mode

    1 310 nm; Single-mode

    1 550 nm; Single-mode

    1 550 nm; Single-mode

    Connectable optical power relative to 1 mW

     

     

     

     

    • of the transmitter output minimum

    -19 dB

    -15 dB

    -5 dB

    1 dB

    • of the transmitter output maximum

    -14 dB

    -8 dB

    0 dB

    5 dB

    • of the receiver input maximum

    -3 dB

    -3 dB

    -3 dB

    -9 dB

    Optical sensitivity relating to 1 mW of the receiver input minimum

    -32 dB

    -34 dB

    -34 dB

    -42 dB

    Damping ratio of the FOC transmission link minimum necessary

    0 dB

    0 dB

    3 dB

    14 dB

    Range at the optical interface depending on the optical fiber used

    0 ... 5 km

    0 ... 26 km

    12 ... 70 km

    61 ... 200 km

    Permitted ambient conditions

     

     

     

     

    Ambient temperature

     

     

     

     

    • during operation

    -40 ... +85 °C

    -40 ... +85 °C

    -40 ... +85 °C

    -40 ... +85 °C

    • during storage

    -40 ... +85 °C

    -40 ... +85 °C

    -40 ... +85 °C

    -40 ... +85 °C

    • during transport

    -40 ... +85 °C

    -40 ... +85 °C

    -40 ... +85 °C

    -40 ... +85 °C

    • Note

    A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours

    A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours

    A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours

    A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours

    Relative humidity at 25 °C without condensation during operation maximum

    95 %

    95 %

    95 %

    95 %

    Protection class IP

    IP20

    IP20

    IP20

    IP20

    Design, dimensions and weight

     

     

     

     

    Design

    SFP Module

    SFP Module

    SFP Module

    SFP Module

    Width

    13.7 mm

    13.7 mm

    13.7 mm

    13.7 mm

    Height

    11.9 mm

    11.9 mm

    11.9 mm

    11.9 mm

    Depth

    56.5 mm

    56.5 mm

    56.5 mm

    56.5 mm

    Net weight

    0.01 kg

    0.01 kg

    0.01 kg

    0.01 kg

    Mounting type

    latched

    latched

    latched

    latched

    Standards, specifications, approvals

     

     

     

     

    Standard

     

     

     

     

    • for FM

    FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

    FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

    FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

    FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

    • for hazardous zone

    EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

    EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

    EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

    EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

    • for safety from CSA and UL

    UL 60950-1, CSA C22.2 No. 60950-1-03

    UL 60950-1, CSA C22.2 No. 60950-1-03

    UL 60950-1, CSA C22.2 No. 60950-1-03

    UL 60950-1, CSA C22.2 No. 60950-1-03

    • for emitted interference

    EN 61000-6-4:2007 (Class A)

    EN 61000-6-4:2007 (Class A)

    EN 61000-6-4:2007 (Class A)

    EN 61000-6-4:2007 (Class A)

    • for interference immunity

    EN 61000-6-2:2005

    EN 61000-6-2:2005

    EN 61000-6-2:2005

    EN 61000-6-2:2005

    Certificate of suitability

    EN 61000-6-2:2005, EN 61000-6-4:2007

    EN 61000-6-2:2005, EN 61000-6-4:2007

    EN 61000-6-2:2005, EN 61000-6-4:2007

    EN 61000-6-2:2005, EN 61000-6-4:2007

    • CE marking

    Yes

    Yes

    Yes

    Yes

    • C-Tick

    Yes

    Yes

    Yes

    Yes

    • KC approval

    No

    No

    No

    No

    MTBF at 40 °C

    120 y

    120 y

    120 y

    120 y


    Order number

    6GK5992-1AL00-8AA0

    6GK5992-1AM00-8AA0

    6GK5992-1AN00-8AA0

    Product type designation

    SFP992-1

    SFP992-1LD

    SFP992-1LH

    Interfaces

     

     

     

    Number of electrical/optical connections for network components or terminal equipment maximum

    1

    1

    1

    Number of optical interfaces for network components or terminal equipment maximum

    1

    1

    1

    Number of 1000 Mbit/s LC ports for single mode (LD) Integrated

    1

    1

    Number of 1000 Mbit/s LC ports for multimode Integrated

    1

    Design of the optical interface for network components or terminal equipment

    LC

    LC

    LC

    Wavelength of the optical interface

    850 nm; Multi-mode

    1 310 nm; Single-mode

    1 550 nm; Single-mode

    Connectable optical power relative to 1 mW

     

     

     

    • of the transmitter output minimum

    -9.5 dB

    -9.5 dB

    -6 dB

    • of the transmitter output maximum

    -4 dB

    -3 dB

    0 dB

    • of the receiver input maximum

    -3 dB

    -3 dB

    -3 dB

    Optical sensitivity relating to 1 mW of the receiver input minimum

    -17 dB

    -21 dB

    -23 dB

    Damping ratio of the FOC transmission link minimum necessary

    0 dB

    0 dB

    3 dB

    Range at the optical interface depending on the optical fiber used

    0 ... 0.75 km

    0 ... 10 km

    8 ... 40 km

    Permitted ambient conditions

     

     

     

    Ambient temperature

     

     

     

    • during operation

    -40 ... +85 °C

    -40 ... +85 °C

    -40 ... +85 °C

    • during storage

    -40 ... +85 °C

    -40 ... +85 °C

    -40 ... +85 °C

    • during transport

    -40 ... +85 °C

    -40 ... +85 °C

    -40 ... +85 °C

    • Note

    A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours

    A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours

    A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours

    Relative humidity at 25 °C without condensation during operation maximum

    95 %

    95 %

    95 %

    Protection class IP

    IP20

    IP20

    IP20

    Design, dimensions and weight

     

     

     

    Design

    SFP Module

    SFP Module

    SFP Module

    Width

    13.7 mm

    13.7 mm

    13.7 mm

    Height

    11.9 mm

    11.9 mm

    11.9 mm

    Depth

    56.5 mm

    56.5 mm

    56.5 mm

    Net weight

    0.01 kg

    0.01 kg

    0.01 kg

    Mounting type

    latched

    latched

    latched

    Standards, specifications, approvals

     

     

     

    Standard

     

     

     

    • for FM

    FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

    FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

    FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

    • for hazardous zone

    EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

    EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

    EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

    • for safety from CSA and UL

    UL 60950-1, CSA C22.2 No. 60950-1-03

    UL 60950-1, CSA C22.2 No. 60950-1-03

    UL 60950-1, CSA C22.2 No. 60950-1-03

    • for emitted interference

    EN 61000-6-4:2007 (Class A)

    EN 61000-6-4:2007 (Class A)

    EN 61000-6-4:2007 (Class A)

    • for interference immunity

    EN 61000-6-2:2005

    EN 61000-6-2:2005

    EN 61000-6-2:2005

    Certificate of suitability

    EN 61000-6-2:2005, EN 61000-6-4:2007

    EN 61000-6-2:2005, EN 61000-6-4:2007

    EN 61000-6-2:2005, EN 61000-6-4:2007

    • CE marking

    Yes

    Yes

    Yes

    • C-Tick

    Yes

    Yes

    Yes

    • KC approval

    No

    No

    No

    MTBF at 40 °C

    120 y

    120 y

    120 y


    Order number

    6GK5992-1AP00-8AA0

    6GK5992-1AQ00-8AA0

    Product type designation

    SFP992-1LH+

    SFP992-1ELH

    Interfaces

     

     

    Number of electrical/optical connections for network components or terminal equipment maximum

    1

    1

    Number of optical interfaces for network components or terminal equipment maximum

    1

    1

    Number of 1000 Mbit/s LC ports for single mode (LD) Integrated

    1

    1

    Design of the optical interface for network components or terminal equipment

    LC

    LC

    Wavelength of the optical interface

    1 550 nm; Single-mode

    1 550 nm; Single-mode

    Connectable optical power relative to 1 mW

     

     

    • of the transmitter output minimum

    0 dB

    0 dB

    • of the transmitter output maximum

    5 dB

    5 dB

    • of the receiver input maximum

    -3 dB

    -8 dB

    Optical sensitivity relating to 1 mW of the receiver input minimum

    -23 dB

    -32 dB

    Damping ratio of the FOC transmission link minimum necessary

    8 dB

    8 dB

    Range at the optical interface depending on the optical fiber used

    30 ... 70 km

    37 ... 120 km

    Permitted ambient conditions

     

     

    Ambient temperature

     

     

    • during operation

    -40 ... +85 °C

    -40 ... +85 °C

    • during storage

    -40 ... +85 °C

    -40 ... +85 °C

    • during transport

    -40 ... +85 °C

    -40 ... +85 °C

    • Note

    A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours

    A maximum ambient operating temperature of +85 °C is permissible for a duration of 16 hours

    Relative humidity at 25 °C without condensation during operation maximum

    95 %

    95 %

    Protection class IP

    IP20

    IP20

    Design, dimensions and weight

     

     

    Design

    SFP Module

    SFP Module

    Width

    13.7 mm

    13.7 mm

    Height

    11.9 mm

    11.9 mm

    Depth

    56.5 mm

    56.5 mm

    Net weight

    0.01 kg

    0.01 kg

    Mounting type

    latched

    latched

    Standards, specifications, approvals

     

     

    Standard

     

     

    • for FM

    FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

    FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

    • for hazardous zone

    EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

    EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

    • for safety from CSA and UL

    UL 60950-1, CSA C22.2 No. 60950-1-03

    UL 60950-1, CSA C22.2 No. 60950-1-03

    • for emitted interference

    EN 61000-6-4:2007 (Class A)

    EN 61000-6-4:2007 (Class A)

    • for interference immunity

    EN 61000-6-2:2005

    EN 61000-6-2:2005

    Certificate of suitability

    EN 61000-6-2:2005, EN 61000-6-4:2007

    EN 61000-6-2:2005, EN 61000-6-4:2007

    • CE marking

    Yes

    Yes

    • C-Tick

    Yes

    Yes

    • KC approval

    No

    No

    MTBF at 40 °C

    120 y

    120 y