CP 1626

  • Заказные данные
    (1)
  • Аксессуары
    (6)
  • Информационные материалы

    Информационные материалы

    • PCI Express module for connecting PCs and SIMATIC PG/PCs to PROFINET IO (3.3 V/12V)
    • Optimized for PROFINET IO
    • With Ethernet real-time ASICs
    • 2 integrated 2-port real-time switches
    • Communication services:
      • PROFINET IO Controller and/or PROFINET IO Device
      • Support of IRT in motion control applications
    • High performance through direct memory access
    • Supply disconnection between IO controller and IO device IP subnet
    • PROFIenergy functions for switching the host PC on and off
    • Integration in network management systems through the support of SNMP
    • Comprehensive diagnostics possibilities for installation, start-up and operation of the module
    • Powerful configuration tools are part of the scope of delivery of the module

    Область применения

    The CP 1626 enables SIMATIC PGs/PCs and PCs equipped with a PCI Express slot to be connected to PROFINET IO.

    The CP 1626 provides high-performance support for control tasks on the PC (PC based Control, Numeric Control, Robot Control).

    With IRT (isochronous real-time), the CP is ideally suited to time-critical applications that are in the range of isochronous closed-loop control in the motion control sector.

    The integrated 2-port switches support low-cost system solutions and the configuration of different topologies.

    The CP 1626 provides SIMATIC programming devices/PCs and industrial PCs with communication functions as:

    • PROFINET IO Controller and/or PROFINET IO Device

    The HARDNET-PN IO Development Kit enables integration of the module into any operating system.

    Дизайн

    • Industrial Ethernet
      • Ethernet real-time ASICs
      • 2 Ethernet interfaces each with 2 x RJ45 ports (2 integrated 2-port real-time switches for 100 Mbps Ethernet)
      • Autosensing/autocrossover/autonegotiation
    • PCI Express interface:
      • PCI Express X1 V1.0a Plug & Play
      • Installation through PCI-Express standard mechanisms (Plug & Play)
    • Host interface/processor:
      • Dual-port RAM on board
      • Flash for program memory onboard
      • ARM 946 RISK processor (32-bit) onboard for preprocessing
    • Ambient conditions

    - Operating temperature from 0 °C to +70 °C

    • Power supply:
      • Operating voltage: 3.3 V/12 V via PCI
      • Optional external 12 to 24 V DC supply for switch mode with PC turned off
    • Size:
      • Short PCIe format

    Функции

    The CP 1626 can be operated as a PROFINET IO controller and/or PROFINET IO device that stores the process image (input and output data) in the memory area on the CP. With simultaneous controller and device mode, only the controller or the device can be operated in IRT mode. High-performance data transfer to and from the IO devices is performed autonomously by the CP 1626.

    Real-time

    Support of real-time properties of PROFINET for RT and IRT. The real-time properties of the CP 1626 ensure extremely short cycle times with highly accurate clock-pulse rates.

    Switching

    According to the industry requirements, the 4-port real-time switch additionally permits the configuration of line topologies with spur lines and makes external switch components unnecessary.

    The switch function is also available in RT mode when the PC is turned off thanks to the possibility of independently supplying an external voltage.

    Energy savings

    Thanks to support from PROFIenergy, it is possible to implement various energy-saving states during idle times on the CP 1626.

    Software packages

    DK HN-IE PN IO development kit;
    driver and IO-Base software for CP 1626 as PROFINET IO controller and IO device under Linux in source code for transfer to any PC-based operating system with IO-Base interface for:

    • PROFINET communication:
      • PROFINET IO controller:
        Connection of field devices to Industrial Ethernet with PROFINET
      • PROFINET IO device:
        Link-up with a PROFINET IO controller through real-time communication according to the PROFINET standard
    • Access in isochronous mode to real-time data for PROFINET over IRT;
      extremely short cycle times with highly accurate clock-pulse rates;
      jitter accuracy, isochronous mode, and cycle time enable high-performance motion control applications.
    • Direct memory access to the process data;
      the process data of the IO-Devices are always consistent. The IO programming interface provides the PC programmer with function calls for data transfer.
    • The design of the interface not only permits fast access as a PROFINET IO controller, but also easy transfer to other operating system environments (e.g. VxWorks, QNX, RMOS, RTX).
    • The IO-Base interface for the PROFINET IO controller of the CP 1626 is compatible with the interface of the CP 1616

    Using the DK HN-IE PN IO development kit included in the scope of delivery, the CP 1626 communications processor can be integrated into any PC-based operating system environment. The development kit contains the driver and IO-Base source code required for this.

    User interfaces

    Programming interface via C library

    For applications that want to use the PROFINET IO-Controller or IO-Device functionality directly over C/C++, the IO-Base interface can be used. This interface is of a similar design to the DP Base interface of PROFIBUS modules CP 5613 and CP 5614. It is therefore possible to port existing PROFIBUS DP master applications to PROFINET IO-Controller applications easily.

    Diagnostics

    Extensive diagnostic options are available via STEP 7 or SNMP, including:

    • General diagnostics functions
    • Connection diagnostics
    • Diagnostics of the assigned PROFINET field devices
    • Integration in network management systems through the support of SNMP

    Configuration

    Configuration of the CP 1626 is performed with STEP7 V14. STEP7 V14 is included in the scope of delivery of the module. A STEP7 license is not required for configuring PC modules.

    Интеграция

    CP 1626 as PROFINET IO controller and PROFINET IO device

    Особенности

    • Connection of field devices to Industrial Ethernet with PROFINET
    • Integrated 2-port switches allow direct connection to PROFINET networks with line or ring topologies and MRP media redundancy
    • Direct memory access to process data by linking as PROFINET IO-Controller via IO-Base interface
    • High computing power is available in the PC by taking the load off the host CPU by means of real-time ASICs with support of the PROFINET real-time features RT and IRT
    • Implementation in Motion Control applications thanks to support of IRT
    • Energy savings thanks to support of PROFIenergy, inc. switching the host PC on and off
    • Simple transfer to various operating system environments using the DK HN-IE PN IO development kit
    • Switch mode also with the PC switched off, via optional external power supply (in RT mode only)
    • Uncrossed connecting cables can be used due to the integrated Autocrossover function

    Технические данные

    Order number

    6GK1162-6AA01

    Transmission rate

     

    Transfer rate

    100 Mbit/s

    Interfaces

     

    Number of electrical connections

     

    • at the 1st interface acc. to Industrial Ethernet

    2

    • at the 2nd interface acc. to Industrial Ethernet

    2

    • for power supply

    1

    Type of electrical connection

     

    • at the 1st interface acc. to Industrial Ethernet

    RJ45 port

    • at the 2nd interface acc. to Industrial Ethernet

    RJ45 port

    Supply voltage, current consumption, power loss

     

    Type of voltage of the supply voltage

    DC

    Supply voltage

     

    • 1 from backplane bus

    3.3 V

    • 2 from backplane bus

    12 V

    • external

    24 V

    • external

    10.5 ... 32 V

    Relative symmetrical tolerance at DC

     

    • at 3.3 V

    9 %

    • at 12 V

    8 %

    Consumed current

     

    • 1 from backplane bus at DC maximum

    2.1 A

    • 2 from backplane bus at DC maximum

    0.1 A

    • from external supply voltage at DC at 12 V maximum

    0.8 A

    • from external supply voltage at DC at 24 V maximum

    0.4 A

    Power loss [W]

    8.1 W

    Power loss [W] in switch mode maximum

    9.6 W

    Permitted ambient conditions

     

    Ambient temperature

     

    • during operation

    0 ... 70 °C

    • during storage

    -20 ... +60 °C

    • during transport

    -20 ... +60 °C

    Relative humidity at 25 °C without condensation during operation maximum

    95 %

    Protection class IP

    IP00

    Design, dimensions and weight

     

    Module format

    PCI Express x1 (half length)

    Width

    21.6 mm

    Height

    126.3 mm

    Depth

    180.5 mm

    Net weight

    110 g

    Number of plug-in cards of same design plug-in per PC station

    1

    Number of units Note

    -

    Performance data

     

    Performance data PROFINET communication as PN IO-Controller

     

    Number of PN IO devices on PROFINET IO controller usable total

    256

    Number of PN IO IRT devices on PROFINET IO controller usable

    64

    Amount of data

     

    • as user data for input variables as PROFINET IO controller maximum

    100 000 byte

    • as user data for input variables as PROFINET IO controller maximum

    100 000 byte

    • as user data for input variables per PN IO device as PROFINET IO controller maximum

    1 430 byte

    • as user data for output variables per PN IO device as PROFINET IO controller maximum

    1 430 byte

    Performance data PROFINET communication as PN IO-Device

     

    Amount of data

     

    • as user data for input variables as PROFINET IO device maximum

    1 430 byte

    • as user data for input variables as PROFINET IO device maximum

    1 430 byte

    • as user data for input variables for each sub-module as PROFINET IO device

    1 024 byte

    • as user data for input variables for each sub-module as PROFINET IO device

    1 024 byte

    • as user data for the consistency area for each sub-module

    1 024 byte

    Number of submodules per PROFINET IO-Device

    512

    Product functions management, configuration

     

    Product function MIB support

    Yes

    Protocol is supported

     

    • SNMP v1

    Yes

    • DCP

    Yes

    • LLDP

    Yes

    Configuration software required

    Included in scope of supply

    Identification & maintenance function

     

    • I&M0 - device-specific information

    Yes

    • I&M1 – higher-level designation/location designation

    Yes

    • I&M2 - installation date

    Yes

    • I&M3 - comment

    Yes

    • I&M4 - signature

    Yes

    • I&M4 - OEM data

    Yes

    Product functions Diagnosis

     

    Product function

     

    • Web-based diagnostics

    Yes

    • Port diagnostics

    Yes

    Product functions switch

     

    Product feature Switch

    Yes

    Product function switch-managed

    No

    Product function with IRT PROFINET IO switch

    Yes

    Product functions Redundancy

     

    Software for redundancy function required

    No

    Product function

     

    • Ring redundancy

    Yes

    • Redundancy manager

    Yes

    Protocol is supported Media Redundancy Protocol (MRP)

    Yes

    Standards, specifications, approvals

     

    Standard

     

    • for EMC

    2004/108/EC

    • for safety from CSA and UL

    CAN/CSA C22.2 & UL 60950-1

    • for emitted interference

    EN 61000-6-3, EN 61000-6-4

    • for interference immunity

    EN 61000-6-1, EN 61000-6-2

    Certificate of suitability

     

    • CE marking

    Yes

    • C-Tick

    Yes


    Дальнейшая информация

    The DK HN-IE PN IO Development Kit is available on the Internet at:
    http://www.siemens.com/simatic-net/DK HN-IE PN IO