SIPLUS extreme RAIL interface modules

  • Заказные данные
    (2)
  • Аксессуары
    (2)
  • Информационные материалы

    Информационные материалы

    Thanks to their wide scope of functions, the interface modules of the scalable SIPLUS extreme RAIL ET 200SP I/O system, even in their basic versions, cover a wide range of applications. The basic functions of the interface modules include:

    • Approved in accordance with the railway standards EN 50155, EN 15121, EN 50124, EN 50125 and EN 45545 for use in rail traffic
    • Short data update times of typically 1 ms
    • Single Hot Swap (withdrawing and insertion of an I/O module during operation without impairing the communication with the remaining modules)
    • Operation with gaps (empty BaseUnits)
    • Complete diagnostic support, extending to channel-by-channel diagnostics
    • Configuration control / option handling (adaptation of the actual configuration via user software)
    • Device replacement without PG I&M data 0 to 3 (electronic rating plate with non-volatile storage of plant data)
    • Firmware update
    • Pluggable 24 V DC supply connection
    • Network / power failure bridging time of 5 ms
    • Labeling option via optional labeling strips and equipment labeling plates

    When using PROFINET interface modules, the following basic functions are also included:

    • Media redundancy (MRP) integrated 2-port switch
    • Freely selectable connection method via SIMATIC BusAdapter
    • Reset button for simple return to factory settings without the need for programming device
    • Replacement without programming device even in case of non-topological configuration with subsequent automatic launching
    • Automatic synchronization of the backplane bus to the PROFINET cycle to minimize the response time fluctuations (jitter)
    SIPLUS ET 200SP IM 155-6PN ST BA TX RAIL with PROFINET interface
    • Max. 32 I/O modules, also PROFIsafe modules with complete diagnostic support.
    • Max. 244 bytes in each case for input and output data per module and per station
    • Data update time: typ. 5 ms
    • PROFIBUS connection via 9-pin SUB-D female connector
    • Package inclusive of server module and PROFIBUS connector with programming device socket

    Область применения

    The SIPLUS ET 200SP IM 155-6PN ST BA TX RAIL is designed mainly for standard PROFINET applications with average station expansion of up to 32 modules (max. 512 IO signals). All I/O modules, including PROFIsafe, can be used.

    Дизайн

    The SIPLUS ET 200SP IM 155-6PN ST BA TX RAIL interface module is snapped directly onto the standard mounting rail (7.5 x 35 mm or 15 x 35 mm).

    • Optional labeling using light gray or yellow labeling strips. There is a choice of 2 materials:
      • Film strips on a roll with 500 strips, for thermal transfer roll printer
      • Card (180 g/m2), DIN A4 sheets with 100 strips each, for laser printer
    • Optional equipment marking using slide-in equipment labeling plates
    • Different connection types of the PROFINET by means of SIMATIC BusAdapter
      • Under ambient conditions in accordance with SIMATIC standard using BA 2xRJ45 for connection via RJ45 plug
      • In the case of mechanical loading during operation and/or an increased EMC requirements BA 2xFC for direct connection of the PROFINET cable

    Технические данные

    Order number

    6AG2155-6AA00-4BN0

    6AG2155-6AU00-4BN0

    SIPLUS ET 200SP IM155-6PN ST BA TX RAIL

    SIPLUS ET 200SP IM155-6PN ST TX RAIL

    General information

     

     

    Product type designation

    IM 155-6 PN ST with BA 2xRJ45 and server module

    IM 155-6 PN ST with server module

    Product function

     

     

    • I&M data

    Yes; I&M0 to I&M3

    Yes; I&M0 to I&M3

    Supply voltage

     

     

    Rated value (DC)

    24 V

    24 V

    Reverse polarity protection

    Yes

    Yes

    Mains buffering

     

     

    • Mains/voltage failure stored energy time

    5 ms

    5 ms

    Hardware configuration

     

     

    Rack

     

     

    • Modules per rack, max.

    32; + 16 ET 200AL modules

    32; + 16 ET 200AL modules

    Submodules

     

     

    • Number of submodules per station, max.

    256

    256

    Interfaces

     

     

    Number of PROFINET interfaces

    1; 2 ports (switch)

    1; 2 ports (switch)

    1. Interface

     

     

    Interface types

     

     

    • Number of ports

    2

    2

    • integrated switch

    Yes

    Yes

    • RJ 45 (Ethernet)

    Yes; Pre-assembled BusAdapter BA 2x RJ45

    • BusAdapter (PROFINET)

    Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC

    Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC

    Functionality

     

     

    • PROFINET IO Device

    Yes

    Yes

    • Open IE communication

    Yes

    Yes

    • Media redundancy

    Yes; PROFINET MRP

    Yes; PROFINET MRP

    Interface types

     

     

    RJ 45 (Ethernet)

     

     

    • Transmission procedure

    PROFINET with 100 Mbit/s full duplex (100BASE-TX)

    PROFINET with 100 Mbit/s full duplex (100BASE-TX)

    • 10 Mbps

    Yes; for Ethernet services

    Yes; for Ethernet services

    • 100 Mbps

    Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)

    Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)

    • Autonegotiation

    Yes

    Yes

    • Autocrossing

    Yes

    Yes

    PROFINET IO Device

     

     

    Services

     

     

    • Isochronous mode

    No

    No

    • Open IE communication

    Yes

    Yes

    • IRT

    Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs

    Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs

    • MRP

    Yes

    Yes

    • MRPD

    No

    No

    • PROFINET system redundancy

    No

    No

    • PROFIenergy

    Yes

    Yes

    • Prioritized startup

    Yes

    Yes

    • Shared device

    Yes

    Yes

    • Number of IO Controllers with shared device, max.

    2

    2

    Open IE communication

     

     

    • TCP/IP

    Yes

    Yes

    • SNMP

    Yes

    Yes

    • LLDP

    Yes

    Yes

    Isochronous mode

     

     

    Isochronous operation (application synchronized up to terminal)

    No

    No

    Interrupts/diagnostics/status information

     

     

    Status indicator

    Yes

    Yes

    Alarms

    Yes

    Yes

    Diagnostic functions

    Yes

    Yes

    Diagnostics indication LED

     

     

    • RUN LED

    Yes; Green LED

    Yes; Green LED

    • ERROR LED

    Yes; Red LED

    Yes; Red LED

    • MAINT LED

    Yes; yellow LED

    Yes; yellow LED

    • Monitoring of the supply voltage (PWR-LED)

    Yes; Green LED

    Yes; Green LED

    • Connection display LINK TX/RX

    Yes; 2x green link LEDs on BusAdapter

    Yes; 2x green link LEDs on BusAdapter

    Isolation

     

     

    Isolation tested with

    707 V DC (type test) and according to EN 50155 (routine test)

    707 V DC (type test) and according to EN 50155 (routine test)

    Standards, approvals, certificates

     

     

    Network loading class

    2

    2

    Security level

    According to Security Level 1 Test Cases V1.1.1

    According to Security Level 1 Test Cases V1.1.1

    Railway application

     

     

    • EN 50121-3-2

    Yes; EMC for rail vehicles

    Yes; EMC for rail vehicles

    • EN 50121-4

    Yes; EMC for signal and telecommunications systems

    Yes; EMC for signal and telecommunications systems

    • EN 50124-1

    Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

    Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

    • EN 50125-1

    Yes; Rail vehicles - see ambient conditions

    Yes; Rail vehicles - see ambient conditions

    • EN 50125-2

    Yes; Stationary electrical equipment - see ambient conditions

    Yes; Stationary electrical equipment - see ambient conditions

    • EN 50125-3

    Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

    Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

    • EN 50155

    Yes; Rail vehicles - temperature class Tx, horizontal mounting position, salt spray Class ST2

    Yes; Rail vehicles - temperature class Tx, horizontal mounting position, salt spray Class ST2

    • EN 61373

    Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

    Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

    • Fire protection acc. to EN 45545-2

    Yes; Rail vehicles - verification on request

    Yes; Rail vehicles - verification on request

    Ambient conditions

     

     

    Ambient temperature during operation

     

     

    • horizontal installation, min.

    -40 °C; = Tmin

    -40 °C; = Tmin

    • horizontal installation, max.

    70 °C; = Tmax; +85 °C for 10 min (Tx acc. to EN 50155)

    70 °C; = Tmax; +85 °C for 10 min (Tx acc. to EN 50155)

    Extended ambient conditions

     

     

    • relative to ambient temperature-atmospheric pressure-installation altitude

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

    Relative humidity

     

     

    • With condensation, tested in accordance with IEC 60068-2-38, max.

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    Resistance

     

     

    • against biologically active substances / conformity with EN 60721-3-3

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

    • against biologically active substances/conformity with EN 60721-3-5

    Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

    Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against chemically active substances / conformity with EN 60721-3-3

    Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    • against chemically active substances/conformity with EN 60721-3-5

    Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

    Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against mechanically active substances / conformity with EN 60721-3-3

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    • against mechanically active substances/conformity with EN 60721-3-5

    Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

    Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

    Dimensions

     

     

    Width

    50 mm

    50 mm

    Height

    117 mm

    117 mm

    Depth

    74 mm

    74 mm

    Weights

     

     

    Weight, approx.

    191 g; IM155PN ST with BA 2x RJ45 (mounted)

    147 g; without BusAdapter

    Other

     

     

    Note:

    For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776

    For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776