- Каталог оборудования Siemens
- Каталог продуктов Siemens Industry
- Приводная техника
- Преобразователи
- Стандартные преобразователи
- Общая информация о базовых преобразователях SINAMICS V
- Преобразователи частоты общего назначения SINAMICS G
- Преобразователи частоты SINAMICS G110
- Компактные преобразователи SINAMICS G120C
- Преобразователи для насосов, вентиляторов,компрессоров SINAMICS G120P
- Обзор
- Введение
- Преобразователи для насосов, вентиляторов, компрессоров SINAMICS G120P
- Integrated Drive Systems
- SINAMICS G120P, built-in and wall-mounted units, IP20/IP54/IP55
- SINAMICS G120P Cabinet, cabinet units, IP20 to IP54
- Selection and engineering tools
- Инженерные инструменты
- Services and documentation
- Инструменты проектирования
- Сервис и документация
- Стандартные преобразователи SINAMICS G120
- SINAMICS G110M distributed inverters
- Преобразователь частоты SINAMICS G110D для распределенной периферии
- Преобразователи частоты SINAMICS G120D
- Преобразователи SINAMICS G130 формат шасси
- Преобразователь частоты SINAMICS G150 шкафного исполнения
- SINAMICS G180
- Высокопроизводительные преобразователи SINAMICS S
- MICROMASTER
- SIPLUS POSMO A
- SIMODRIVE POSMO
- LOHER DYNAVERT Drive System
- Преобразователи на среднее напряжение
- Преобразователи постоянного тока
- Стандартные преобразователи
- Двигатели переменного тока
- Generators
- Мотор-редукторы
- Flender Gear Units
- Couplings
- Инструментальное программное обеспечение
- Дополнительные компоненты
- Преобразователи
- Техника автоматизации
- Energy
- Автоматизация и безопасность зданий
- Низковольтная коммутационная техника
- Технология безопасности
- Системные решения и продукты для отраслей
- Сервис
- Приводная техника
- Заказные данные (2)
- Информационные материалы
Информационные материалы
Sine-wave filter
Sine-wave filters limit the the rate of voltage rise (dv/dt) and the peak voltages on the motor winding. Similar to an output reactor, they enable the connection of longer motor cables.
Bearing currents are also reduced significantly. Using these filters therefore allows standard motors with standard insulation and without insulated bearings to be operated on SINAMICS. As a result, the voltage load on the motor winding is virtually identical to the load on windings of directly mains-fed motors.
Owing to the very low rates of voltage rise on the motor cable, the sine-wave filter also has a positive impact in terms of electromagnetic compatibility which means that it is not absolutely essential to use shielded cables for short motor cables to achieve the required standard of EMC.
Since the voltage applied to the motor is not pulsed, the inverter-related stray losses and additional noise in the motor are also reduced considerably and the noise level of the motor is similar to the level produced by directly mains-fed motors.
When using sine-wave filters, the following should be observed:
- Pulse frequencies of between 4 kHz and 8 kHz are permissible for rated outputs up to and including 90 kW
- Only a pulse frequency of 4 kHz is permissible for rated outputs of 110 kW and higher. Note additional current derating as compared with rated pulse frequency of 2 kHz (see derating data)
- The output frequency is limited to 150 Hz.
- Operation and commissioning may only be performed with the motor connected as the sine-wave filter is not no-load proof
- It must be ensured that the automatic pulse frequency reduction functions are also deactivated
- A derating of 5 % must be observed when the appropriate PM240 Power Module is selected
Интеграция
Available optional sine-wave filters
Frame size
FSF
PM240 Power Module with integrated braking chopper
Load-side power components
Sine-wave filter
S
S = Lateral mounting
Технические данные
Line voltage 380 ... 480 V 3 AC
Sine-wave filter (for pulse frequencies 4 ... 8 kHz, only 4 kHz permissible at 110 kW and above – note additional current derating as compared with rated pulse frequency of 2 kHz, see derating data)
6SL3202-0AE31-8SA0
6SL3000-2CE32-3AA0
Rated current
A
182
225
225
Power loss
kW
0.47
0.221
0.221
Connection to the Power Module
Screw terminals
1 x hole for M10
1 x hole for M10
- Conductor cross-section
mm2
150
Motor connection
Screw terminals
1 x hole for M10
1 x hole for M10
- Conductor cross-section
mm2
150
PE connection
M8 screw
1 x hole for M10
1 x hole for M10
Cable length, max.
between sine-wave filter and motor
- 380 ... 480 V ±10 % 3 AC
- Shielded
m (ft)
200 (656)
300 (984)
300 (984)
- Unshielded
m (ft)
300 (984)
450 (1476)
450 (1476)
Dimensions
- Width
mm (in)
350 (13.8)
620 (24.4)
620 (24.4)
- Height
mm (in)
468 (18.4)
300 (11.8)
300 (11.8)
- Depth
mm (in)
305 (12.0)
320 (12.6)
320 (12.6)
Degree of protection
IP00
IP00
IP00
Weight, approx.
kg (lb)
80 (176)
124 (273)
124 (273)
Suitable for
PM240 Power ModuleType
6SL3224-0BE37-5UA0
6SL3224-0BE37-5AA0
6SL3224-0BE38-8UA0
6SL3224-0BE41-1UA0
- Rated power of the Power Module
kW (hp)
90 (121)
110 (148)
132 (177)
- Rated current Irated of the Power Module
A
178
205
250
- Frame size
FSF
FSF
FSF