    General description

    LOHER DYNAVERT T can be flexibly integrated into any automation concept – whether using conventional control technology or bus systems.

    LOHER DYNAVERT T can be connected to any of the normally encountered line supply voltages – and can feed both synchronous and asynchronous motors. All of the drive requirements are taken into consideration from the word go – from the coupling, through the motor, cables, drive inverter, line supply situation and connection to the supervisory control system.

    Features

    Explosion protection

    • ATEX‑certified for motors located in hazardous zones
    • A main contactor is not required

    Safe Torque Off

    • The Safe Torque Off function prevents unexpected starting in compliance with EN 60204‑1, implemented according to EN 954‑1, Category 3

    Power unit

    • This corresponds to the EMC Directives (EN 61800-3 environment 2) as a result of the line filter integrated as standard·
    • Low harmonics fed back into the line supply as a result of the integrated line reactor
    • Output filter to permit longer motor cables
    • Insulation monitoring for IT line supplies for 500/690 V drive units as well as ground fault monitoring for TN and TT line supplies integrated in the 400 V drive units
    • Wide supply voltage range
    • Low motor noise and low drive inverter and motor losses as a result of the optimized pulse pattern
    • Normal fuses can be used for protection (gL characteristic)

    Control section

    • High level of personnel and plant protection through protective separation between the analog and digital control peripheral and the power unit according to VDE 0106/EN 50178

    Operator control and setting

    • Transparent operator control and setting using a menu-prompted 4-line plain text display with membrane keypad at the drive inverter – or up to 1,000 m away in the main control room via RS485
    • Extensive functions using the Windowsbased PC operator control program

    Communication

    • Communication via a conventional terminal strip with freely‑programmable digital and analog inputs/outputs, with
      • parameterizable limit value signals
      • parameterizable timers
      • parameterizable damping elements
      • parameterizable drive inverter behavior when inputs/outputs respond
    • Communication and parameterization via
      • PC using IMS (Inverter Management Software) via RS232/RS485
      • external operator panel via RS485
      • bus systems such as PROFIBUS DP or Modbus RTU

    Drive behavior for LOHER DYNAVERT T

    • Synchronous and asynchronous motors can be controlled
    • Two closed‑loop control types for induction motors:
      • field‑oriented control for applications demanding a high dynamic performance
      • space‑vector control for standard applications (without feedback)
    • Optimum braking without supplementary equipment using super‑saturation control

    The following generally apply

    • Automatic slip compensation
    • Stall protection using current limiting control
    • Flying restart circuit to connect to a rotating motor
    • Automatic adaptation of the overload times
    • Parameterizable DC braking for precise braking down to standstill
    • Closed‑loop torque control

    Область применения

    Typical applications
    • Power stations and utilities
    • Plastic industry
    • Basic materials industry
    • Test stands
    • Conveyor technology
    • Applications in general machinery construction

    Особенности

    Customer benefits
    • Cabinet units and cabinet systems in IP21 or higher degrees of protection
    • All of the drive units have their own connection space
    • Compact dimensions
    • Equipped with radio interference suppression
    • Low harmonics fed back into the line supply
    • Long motor cables can be used as a result of the integrated dv/dt filter
    • Wide supply voltage range
    • A main contactor is not required
    • Drive units with 500 V and 690 V rated line supply voltage can be connected to non‑grounded line supplies (IT line supplies)
    • ATEX‑certified motors for hazardous zones

    Технические данные

    Technical data overview

    Rated input voltage

    Typ. motor rated power compact units

    Typ. motor rated power cabinet units/cabinet systems

    400 V

    2.2 ... 160 kW

    2.2 ... 630 kW

    500 V

    2.2 ... 200 kW

    2.2 ... 800 kW

    690 V

    7.5 ... 200 kW

    7.5 ... 6000 kW



    Brief overview

    Line supply voltage
    +10 %, -15 %

    3 ~ AC 230 ... 500 V (for TN/TT line supplies)
    3 ~ AC 230 ... 415 V (for TN/TT line supplies)
    3 ~ AC 230 ... 500 V (for IT line supplies)
    3 ~ AC 400 ... 690 V (for TN/TT/IT line supplies)

    Line supply cos φ (1)

    approx. 0.99

    Line supply frequency

    47 ... 63 Hz

    Maximum output frequency

    120 ... 250 Hz (Setting range depends on the unit power rating)

    Output voltage (basic fundamental)

    3 × 0 ... line supply voltage

    Clock frequency

    1.5 ... 10 kHz, can be parameterized (Setting range depends on the unit power rating)

    Motor cable length
    (shielded or non-shielded)

    200 ... 300 m (690 V: 100 to 300 m)

    Degree of protection:
    Compact drive units
    Cabinet units/systems

     
    IP20